Xalqaro tadqiqotlarning qiyosiy tahlili asosida Passive House turar joylarini O‘zbekiston sharoitiga moslashtirishni baholash
- Authors
-
-
Umarkulova Shaxodat Mashrab qizi
Toshkent arxitektura-qurilish universiteti assistenti, Toshkent, O‘zbekiston
Author
-
- Keywords:
- Array
- Abstract
-
This article aims to comparatively analyze international studies on Passive House residential buildings and propose an approach for assessing how their design solutions could be adapted to conditions in Uzbekistan. Twenty purposively selected studies were analyzed in terms of energy performance, summer thermal comfort, climate responsive architectural design, and operational monitoring. The findings indicate that building orientation, glazing, shading, the building envelope, ventilation, and occupancy patterns should be assessed together. Measures that reduce heating demand should also be evaluated for their effects on cooling demand and the risk of summer overheating. The comparison further shows that differences in climate, building configuration, occupancy, and monitoring conditions must be considered when interpreting the energy performance reported for projects in other countries. The article proposes an assessment approach that identifies the conditions under which a solution performs effectively, determines what requires local verification, selects an adaptation measure, and specifies how its performance should be evaluated. Future research should assess the resulting design solutions through energy simulation across different climatic regions of Uzbekistan and verify their operational performance through monitoring of pilot buildings.
- Downloads
-
Download data is not yet available.
- References
-
1.International Energy Agency. (2025). Energy Efficiency 2025: Buildings. https://www.iea.org/reports/energy-efficiency-2025/buildings
2.International Energy Agency. (2020). Uzbekistan energy profile. https://www.iea.org/reports/uzbekistan-energy-profile
3.Umarkulova Shaxodat Mashrab qizi, Ashirmatova Nigina Baxodir, & Otabekova Laylo Umirbekovna. (2026). Zamonaviy arxitekturada energiya samarador binolarni loyihalashda powerhouse loyihalari asosida barqaror dizayn yechimlarining qiyosiy tahlili. In Problems of architecture and construction (Vol. 4, Issue 2, pp. 45–55). Zenodo. https://doi.org/10.5281/zenodo.20629023
4.Anand, V., Kadiri, V. L., & Putcha, C. (2023). Passive buildings: A state-of-the-art review. Journal of Infrastructure Preservation and Resilience, 4, 3. https://doi.org/10.1186/s43065-022-00068-z
5.Johnston, D., Siddall, M., Ottinger, O., Peper, S., & Feist, W. (2020). Are the energy savings of the passive house standard reliable? A review of the as-built thermal and space heating performance of passive house dwellings from 1990 to 2018. Energy Efficiency, 13, 1605–1631. https://doi.org/10.1007/s12053-020-09855-7.
6.Sharipov, K. A., Avezova, N. R., & Salomov, U. R. (2026). Review of International and National Experience in Passive House Development. Problems of Energy and Sources Saving, (2), 74–92. https://energy.tdtu.uz/index.php/journal/article/view/188
7.Norov, N. N. (2020). Passiv quyosh isitish tizimli kam qavatli turar-joy binolarining konstruktiv yechimi [Monografiya]. Toshkent arxitektura-qurilish instituti.
8.Avezova, N. R., Avezov, R. R., Rashidov, Y. K., & Samiev, K. A. (2014). Model-based analysis of nonstationary thermal mode in premises with an insolation passive heating system with a three-layer translucent shield. Applied Solar Energy, 50, 184–187.
9.Turdalieva, M. K., Arslanov, I. K., & Khasanov, J. O. U. (2026). Optimization of the connection node of the external wall, interfloor slab, balcony slab and seismic belt for improving thermal efficiency. The American Journal of Interdisciplinary Innovations and Research, 8(3), 9–14. https://doi.org/10.37547/tajiir/Volume08Issue03-02
10.Samiev, K. A., & Halimov, A. S. (2022). Annual thermal performance of the Trombe wall with phase change heat storage under climate conditions of Uzbekistan. Applied Solar Energy, 58(2), 297–305. https://doi.org/10.3103/S0003701X22020189
11.Halimov, A., Akhatov, J., & Iskandarov, Z. (2024). Optimization of phase change material properties for enhanced thermal performance in building envelopes. Applied Solar Energy, 60(4), 636–648. https://doi.org/10.3103/S0003701X22600424
12.Shnekeev, J. K. (2020). Traditional settlements of the South Aral Sea (Traditional housing of the South Aral Sea region). Solid State Technology, 63(5).
13.D’Agostino, D., & Mazzarella, L. (2019). What is a Nearly zero energy building? Overview, implementation and comparison of definitions. Journal of Building Engineering, 21, 200–212. https://doi.org/10.1016/j.jobe.2018.10.019
14.Taherahmadi, J., Noorollahi, Y., & Panahi, M. (2021). Toward comprehensive zero energy building definitions: A literature review and recommendations. International Journal of Sustainable Energy, 40(2), 120–148. https://doi.org/10.1080/14786451.2020.1796664
15.Passive House Institute. (2023). Criteria for the Passive House, EnerPHit and PHI Low Energy Building Standards. Passive House Institute. https://passivehouse.com/downloads/03_building_criteria_en.pdf
16.Passive House Institute. (n.d.). Passive House Database. https://passivehouse-database.org/
17.Nguyen, A.-T., Reiter, S., & Rigo, P. (2014). A review on simulation-based optimization methods applied to building performance analysis. Applied Energy, 113, 1043–1058. https://doi.org/10.1016/j.apenergy.2013.08.061
18.Tian, W. (2013). A review of sensitivity analysis methods in building energy analysis. Renewable and Sustainable Energy Reviews, 20, 411–419. https://doi.org/10.1016/j.rser.2012.12.014
19.Coakley, D., Raftery, P., & Keane, M. (2014). A review of methods to match building energy simulation models to measured data. Renewable and Sustainable Energy Reviews, 37, 123–141. https://doi.org/10.1016/j.rser.2014.05.007
20.de Wilde, P. (2014). The gap between predicted and measured energy performance of buildings: A framework for investigation. Automation in Construction, 41, 40–49. https://doi.org/10.1016/j.autcon.2014.02.009
21.Schnieders, J., Feist, W., & Rongen, L. (2015). Passive Houses for different climate zones. Energy and Buildings, 105, 71–87. https://www.sciencedirect.com/science/article/pii/S0378778815301481
22.Khalfan, M., & Sharples, S. (2016). The present and future energy performance of the first Passivhaus project in the Gulf region. Sustainability, 8(2), 139. https://doi.org/10.3390/su8020139
23.Alnashri, H. A., Fnais, A. S., & Bin Mahmoud, A. A. (2025). Barriers and strategies for implementing Passive House design: The case of the construction sector in Saudi Arabia. Buildings, 15(17), 3117. https://doi.org/10.3390/buildings15173117
24.Figueiredo, A., Kämpf, J., & Vicente, R. (2016). Passive house optimization for Portugal: Overheating evaluation and energy performance. Energy and Buildings, 118, 181–196. https://www.sciencedirect.com/science/article/pii/S0378778816300925
25.Figueiredo, A., Figueira, J., Vicente, R., & Maio, R. (2016). Thermal comfort and energy performance: Sensitivity analysis to apply the Passive House concept to the Portuguese climate. Building and Environment, 103, 276–288. https://doi.org/10.1016/j.buildenv.2016.03.031
26.Fokaides, P. A., Christoforou, E., Ilic, M., & Papadopoulos, A. (2016). Performance of a Passive House under subtropical climatic conditions. Energy and Buildings, 133, 14–31. https://www.sciencedirect.com/science/article/pii/S0378778816309586
27.Mlakar, J., & Štrancar, J. (2011). Overheating in residential passive house: Solution strategies revealed and confirmed through data analysis and simulations. Energy and Buildings, 43, 1443–1451.
28.Borrallo-Jiménez va boshq. (2022). Comparative study between the Passive House Standard in warm climates and Nearly Zero Energy Buildings under Spanish Technical Building Code in a dwelling design in Seville, Spain. Energy and Buildings, 254, 111570.
29.Potrč Obrecht, T., Premrov, M., & Žegarac Leskovar, V. (2019). Influence of the orientation on the optimal glazing size for passive houses in different European climates (for non-cardinal directions). Solar Energy, 189, 15–25.
30.Li, Y., va boshq. (2023). Energy Consumption of Apartment Conversion into Passive Houses in Hot-Summer and Cold-Winter Regions of China. Buildings, 13(1), 168. https://doi.org/10.3390/buildings13010168
31.Li, X., Deng, Q., Ren, Z., Shan, X., & Yang, G. (2021). Parametric Study on Residential Passive House Building in Different Chinese Climate Zones. Sustainability, 13(8), 4416. https://doi.org/10.3390/su13084416
32.Han, F., Liu, B., Feist, W., Pfluger, R., & Dermentzis, G. (2023). Operational performance evaluation of a Passive house residential building in northern China based on long-term monitoring in winter. Indoor and Built Environment, 32, 1464–1486. https://doi.org/10.1177/1420326X231169874
33.Dan, D., va boshq. (2016). Passive house design—An efficient solution for residential buildings in Romania. Energy for Sustainable Development, 32, 99–109.
34.Mihai, M., Tanasiev, V., Dinca, C., Badea, A., & Vidu, R. (2017). Passive house analysis in terms of energy performance. Energy and Buildings, 144, 74–86.
35.Wąs, K., Radoń, J., & Sadłowska-Sałęga, A. (2020). Maintenance of Passive House Standard in the Light of Long-Term Study on Energy Use in a Prefabricated Lightweight Passive House in Central Europe. Energies, 13(11), 2801. https://doi.org/10.3390/en13112801
36.Rohdin, P., Molin, A., & Moshfegh, B. (2014). Experiences from nine passive houses in Sweden—Indoor thermal environment and energy use. Building and Environment, 71, 176–185.
37.Sameni, S., Gaterell, M., Montazami, A., & Ahmed, A. (2015). Overheating investigation in UK social housing flats built to the Passivhaus standard. Building and Environment, 92, 222–235.
38.Finegan, E., Kelly, G., & O’Sullivan, G. (2020). Comparative analysis of Passivhaus simulated and measured overheating frequency in a typical dwelling in Ireland. Building Research & Information, 48(6), 681–699.
39.Ridley, I., va boshq. (2013). The monitored performance of the first new London dwelling certified to the Passive House standard. Energy and Buildings, 63, 67–78.
40.Feist, W., Pfluger, R., & Hasper, W. (2020). Durability of building fabric components and ventilation systems in passive houses. Energy Efficiency, 13, 1543–1559.
41.Schnieders, J., & Hermelink, A. (2006). CEPHEUS results: Measurements and occupants’ satisfaction provide evidence for Passive Houses being an option for sustainable building. Energy Policy, 34(2), 151–171.
42.Mirhosseini, H., Li, J., Iulo, L. D., & Freihaut, J. D. (2024). Quantifying the Enhanced Performance of Multifamily Residential Passive House over Conventional Buildings in Terms of Energy Use. Buildings, 14(6), 1866. https://doi.org/10.3390/buildings14061866
43.Moreno-Rangel, A., Sharpe, T., McGill, G., & Musau, F. (2021). Thermal comfort assessment of the first residential Passivhaus in Latin America. Journal of Building Engineering, 43, 103081.
44.Attia, S., Hamdy, M., O’Brien, W., & Carlucci, S. (2013). Assessing gaps and needs for integrating building performance optimization tools in net zero energy buildings design. Energy and Buildings, 60, 110–124. https://doi.org/10.1016/j.enbuild.2013.01.016
45.Mitchell, R., & Natarajan, S. (2019). Overheating risk in Passivhaus dwellings. Building Services Engineering Research and Technology, 40(4), 446–469. https://doi.org/10.1177/0143624419842006
46.Farrokhirad, E., Gao, Y., Pitts, A., & Chen, G. (2024). A Systematic Review on the Risk of Overheating in Passive Houses. Buildings, 14(8), 2501. https://doi.org/10.3390/buildings14082501
47.Goncalves, V. L., Costanzo, V., Fabbri, K., & Rakha, T. (2022). Overheating assessment in Passivhaus dwellings: The influence of prediction tools. Buildings and Cities, 3(1), 153–167. https://doi.org/10.5334/bc.151
48.Nicol, J. F., & Humphreys, M. A. (2002). Adaptive thermal comfort and sustainable thermal standards for buildings. Energy and Buildings, 34(6), 563–572. https://doi.org/10.1016/S0378-7788(02)00006-3
49.Albayyaa, H., Hagare, D., & Saha, S. (2019). Energy conservation in residential buildings by incorporating Passive Solar and Energy Efficiency Design Strategies and higher thermal mass. Energy and Buildings, 182, 205–213. https://doi.org/10.1016/j.enbuild.2018.09.036
- Downloads
- Published
- 2026-09-29
- Section
- Articles